DICOM images
DICOM images in the repository
A DICOM file is one document in the repository. Its image opens in the portal's viewer, drawn by the server: the browser receives pictures only, never the file or the header that carries the patient's name, ID and date of birth.
Recognised on upload
A DICOM file (.dcm) is recognised by its content, even when the browser sends a generic file type. A single file with one or several frames is supported, uncompressed or compressed with RLE, JPEG, JPEG-LS or JPEG 2000.
Technical values fill the fields
Modality, body part, equipment, image size, number of frames, the study, series and instance identifiers and the burned-in annotation flag are read from the header and fill the document's fields that a manager has linked to them.
Patient values wait for a person
Patient name, ID, birth date and sex, accession number, referring physician, institution and study date are suggested for review and never filled silently. Only what a person confirms enters a field.
A viewer in the portal
A frame slider, window presets for CT (soft tissue, lung, bone) and Fit or 100% zoom. A tag panel lists non-personal tags only. Every image carries "For reference only, not for diagnosis", and a warning when it may show patient data burned into the picture.
Pixels only to the browser
The server draws each frame and sends a picture. The file itself goes out only as a download, to people with the download right; the portal never shows its header.
Images attached to a report
An ultrasound report with its images: attached DICOM files are marked and counted, and they open in the same viewer, under the report's own access rights.
Guarded as health data
When the repository protects the file content of documents with sensitive data, a DICOM image always requires the right to view sensitive data. People without it can see that the documents exist, not the images.
Sealed, corrected and exported with care
A sealed original is shown as watermarked frames and cannot be downloaded. Rectification and erasure reach the extracted values, and the native export leaves the patient data out.
Decoders pinned and verified
The libraries that decode the images are fixed at exact versions and checked against recorded checksums, so a changed file stops the build.
What it does not do
- It is not a PACS. No PACS or DICOMweb connection, and no ZIP or DICOMDIR studies: files come in by upload, one at a time.
- It is not for diagnosis. No measurements, annotations, 3D or multi-planar views; the viewer shows one frame at a time, for reference only. Archystream is not a medical device.
- It does not de-identify images. Patient data in the pixels or in the file is not removed or blurred, and erasure does not edit the DICOM file; the viewer warns when an image may show patient data.
- Attached images do not fill the report. Values are read from DICOM documents on upload, not from images attached to another document.
- Some images cannot be drawn. Video formats and compressions the server cannot decode are reported as such; the file can still be downloaded by someone with the download right.
See Archystream with your own documents
Tell us about your record series and we will walk you through a portal configured for them, including the description quality we measure on documents like yours.